PM Node
Hardware revisions, in order

Where it stands

Status
Rev 01Display replaced — moved to the ST7796.
Rev 02Joystick removed; pointer-driven navigation dropped.
Rev 03KY-040 rotary encoder adopted as the single control.
Rev 04Vibration sensor replaced with the IIS3DWB.
Rev 05SPI bus conflicts resolved between the display, sensor and SD.

Implemented

  • — ST7796 TFT display init and landscape UI rendering
  • — Rotary encoder navigation with interrupt-based page switching
  • — Local Wi-Fi access point and web server
  • — IIS3DWB vibration sensing, live values and FFT pipeline
  • — MLX90640 thermal detection and display logic
  • — DS18B20 probe temperature with a dedicated page
  • — Sound acquisition with FFT support
  • — Recording workflow tied to the encoder button
  • — microSD detection and storage

Partially implemented

  • — Final TFT page polish for all trend plots and labels
  • — Web and TFT parity for all page structures
  • — Mount-state-aware interpretation refinement
  • — Production-quality logging and error presentation

Next steps

  • — Finalize TFT layouts for every live page
  • — Improve selective-redraw for smoother TFT updates
  • — Finalize web/TFT feature parity
  • — Document wiring, pin mappings and enclosure design

Not production ready yet. This is an advanced prototype — core sensing and interaction patterns work, but hardware robustness, calibration, documentation and validation still need work.